 2026/01/13                                ENABLE GAS TRANSMISSION, LLC                 PAGE:     1                                                                                                                                                       
 MVRP3020-53                                   GAS SAMPLE ANALYSIS                         MVNX3020                                                                                                                                                       
                                                                                           TIME: 15:01:201                                                                                                                                                
                                                                                                                                                                                                                                                          
                                                                                                                                                                                                                                                          
         Location              Gas Day    Gravity    BTU     CO2 %    N2 %    Oxygen %   H2S %   Methane %  Ethane %  Propane %  I-Butane %  N-Butane %  Neo-Pentane %  I-Pentane %  N-Pentane %  Hexanes %  N-Heptane %  N-Octane %  N-Nonane %          
                                                                                 O2                 C1         C2        C3                                   C5                                     C6          C7           C8          C9              
  -----------------------     ----------  -------  -------  -------  -------  --------  -------  ---------  --------  ---------  ----------  ----------  -------------  -----------  -----------  ---------  -----------  ----------  ----------          
                                                                                                                                                                                                                                                          
  BAY CHECK GC @ 170610       2026/01/12  0.5874   1.02907  1.0962   00.5338  00.0000   00.0000  94.5065    03.6852   00.1546    00.0074     00.0089     00.0000        00.0023      00.0016      00.0014    00.0010      00.0005     00.0000             
  CUSTER ST @ LINE AD ST1     2026/01/12  0.5791   1.01901  0.5441   01.1887  00.0000   00.0000  95.5398    02.5562   00.1636    00.0028     00.0044     00.0000        00.0000      00.0000      00.0000    00.0000      00.0000     00.0000             
  GLENDALE CEGT TO MRT @      2026/01/12  0.5979   1.04717  0.7403   00.9836  00.0000   00.0000  92.0041    06.0322   00.2130    00.0062     00.0091     00.0000        00.0018      00.0014      00.0036    00.0027      00.0013     00.0000             
  CHANDLER ST DISCHARGE G     2026/01/12  0.5993   1.05030  0.6921   00.9990  00.0000   00.0000  91.6797    06.3587   00.2514    00.0070     00.0072     00.0000        00.0013      00.0010      00.0010    00.0007      00.0003     00.0000             
  FM 63 - Columbia GC @ 2     2026/01/12  0.6060   1.08305  0.1933   00.4184  00.0000   00.0000  90.2544    08.6340   00.3991    00.0322     00.0448     00.0000        00.0093      00.0067      00.0034    00.0025      00.0012     00.0000             
                                                                                                                                                                                                                                                          
                                                                                                                                                                                                                                                          
                                                                                                                                                                                                                                                          
 The information displayed above reflects daily average gas quality readings                                                                                                                                                                              
 taken at key locations on the EGT system.  The dates shown above are the                                                                                                                                                                                 
 dates of the readings. The readings are taken daily, and information from such                                                                                                                                                                           
 readings is posted on the first day thereafter.  If on any reading day there                                                                                                                                                                             
 are problems retrieving the data, the last reported readings will remain                                                                                                                                                                                 
 posted until such time as new readings are obtained.  Due to factors such as                                                                                                                                                                             
 equipment failure, sample contamination and human error, the information                                                                                                                                                                                 
 displayed above may not be completely accurate.