EGT Gas Quality Daily Sample Report

                                                                                                                                                                                                                                                    
                                                                                                                                                                                                                                                 
 2026/01/27                                ENABLE GAS TRANSMISSION, LLC                 PAGE:     1                                                                                                                                                       
 MVRP3020-53                                   GAS SAMPLE ANALYSIS                         MVNX3020                                                                                                                                                       
                                                                                           TIME: 15:01:179                                                                                                                                                
                                                                                                                                                                                                                                                          
                                                                                                                                                                                                                                                          
         Location              Gas Day    Gravity    BTU     CO2 %    N2 %    Oxygen %   H2S %   Methane %  Ethane %  Propane %  I-Butane %  N-Butane %  Neo-Pentane %  I-Pentane %  N-Pentane %  Hexanes %  N-Heptane %  N-Octane %  N-Nonane %          
                                                                                 O2                 C1         C2        C3                                   C5                                     C6          C7           C8          C9              
  -----------------------     ----------  -------  -------  -------  -------  --------  -------  ---------  --------  ---------  ----------  ----------  -------------  -----------  -----------  ---------  -----------  ----------  ----------          
                                                                                                                                                                                                                                                          
  BAY CHECK GC @ 170610       2026/01/26  0.5906   1.02933  1.2580   00.5737  00.0000   00.0000  93.9957    03.9954   00.1591    00.0056     00.0070     00.0000        00.0016      00.0012      00.0010    00.0008      00.0003     00.0000             
  CUSTER ST @ LINE AD ST1     2026/01/26  0.5574   1.01851  0.0000   00.0000  00.0000   00.0000  99.8162    00.0000   00.0000    00.0000     00.1837     00.0000        00.0000      00.0000      00.0000    00.0000      00.0000     00.0000             
  GLENDALE CEGT TO MRT @      2026/01/26  0.5983   1.04678  0.7674   00.9956  00.0000   00.0000  91.9937    05.9787   00.2347    00.0071     00.0102     00.0000        00.0023      00.0016      00.0038    00.0028      00.0013     00.0000             
  CHANDLER ST DISCHARGE G     2026/01/26  0.6016   1.04944  0.9347   00.8939  00.0000   00.0000  91.4993    06.3860   00.2608    00.0084     00.0097     00.0000        00.0018      00.0015      00.0017    00.0012      00.0006     00.0000             
  FM 63 - Columbia GC @ 2     2026/01/26  0.6043   1.08082  0.1984   00.3911  00.0000   00.0000  90.6125    08.2840   00.4103    00.0358     00.0446     00.0000        00.0094      00.0057      00.0036    00.0027      00.0013     00.0000             
                                                                                                                                                                                                                                                          
                                                                                                                                                                                                                                                          
                                                                                                                                                                                                                                                          
 The information displayed above reflects daily average gas quality readings                                                                                                                                                                              
 taken at key locations on the EGT system.  The dates shown above are the                                                                                                                                                                                 
 dates of the readings. The readings are taken daily, and information from such                                                                                                                                                                           
 readings is posted on the first day thereafter.  If on any reading day there                                                                                                                                                                             
 are problems retrieving the data, the last reported readings will remain                                                                                                                                                                                 
 posted until such time as new readings are obtained.  Due to factors such as                                                                                                                                                                             
 equipment failure, sample contamination and human error, the information                                                                                                                                                                                 
 displayed above may not be completely accurate.