2026/03/11 ENABLE GAS TRANSMISSION, LLC PAGE: 1
MVRP3020-53 GAS SAMPLE ANALYSIS MVNX3020
TIME: 15:01:180
Location Gas Day Gravity BTU CO2 % N2 % Oxygen % H2S % Methane % Ethane % Propane % I-Butane % N-Butane % Neo-Pentane % I-Pentane % N-Pentane % Hexanes % N-Heptane % N-Octane % N-Nonane %
O2 C1 C2 C3 C5 C6 C7 C8 C9
----------------------- ---------- ------- ------- ------- ------- -------- ------- --------- -------- --------- ---------- ---------- ------------- ----------- ----------- --------- ----------- ---------- ----------
BAY CHECK GC @ 170610 2026/03/10 0.5825 1.02295 0.8279 00.8487 00.0000 00.0000 95.2288 02.8973 00.1620 00.0107 00.0139 00.0000 00.0037 00.0026 00.0019 00.0014 00.0007 00.0000
CUSTER ST @ LINE AD ST1 2026/03/10 0.5705 1.01020 0.3095 01.2659 00.0000 00.0000 96.9152 01.4731 00.0337 00.0008 00.0015 00.0000 00.0000 00.0000 00.0000 00.0000 00.0000 00.0000
GLENDALE CEGT TO MRT @ 2026/03/10 0.5825 1.02428 0.6987 00.9615 00.0000 00.0000 95.0056 03.2119 00.1005 00.0054 00.0080 00.0000 00.0018 00.0013 00.0022 00.0017 00.0008 00.0000
CHANDLER ST DISCHARGE G 2026/03/10 0.5817 1.02272 0.7305 00.9291 00.0000 00.0000 95.1843 03.0456 00.0941 00.0055 00.0062 00.0000 00.0014 00.0010 00.0009 00.0006 00.0003 00.0000
FM 63 - Columbia GC @ 2 2026/03/10 0.6065 1.08398 0.1893 00.4209 00.0000 00.0000 90.0065 08.9750 00.3384 00.0232 00.0304 00.0000 00.0064 00.0040 00.0025 00.0019 00.0009 00.0000
The information displayed above reflects daily average gas quality readings
taken at key locations on the EGT system. The dates shown above are the
dates of the readings. The readings are taken daily, and information from such
readings is posted on the first day thereafter. If on any reading day there
are problems retrieving the data, the last reported readings will remain
posted until such time as new readings are obtained. Due to factors such as
equipment failure, sample contamination and human error, the information
displayed above may not be completely accurate.